Networking & decentralisation
 |
 |
|
Panasonic Ethernet
|
All relevant factory automation products communicate with each other via Ethernet. Main focus is the connection to the IT-world and the use of its advantages: - uses existing networks, saves wiring - reaches almost every point of the world via Internet - standard software tools already existing on your PC - remote control, monitoring and programming
The FP Web-Server brings together all the FP series controllers with Ethernet an all the possibilities of this new technology. In addition, for the FP2 / FP2SH series controllers, Panasonic provides high-end ET-LAN modules for particularly fast communication on the Ethernet network.
|
 |
 |
|
Panasonic PROFIBUS
|
Implies manufacturer-independent communication at the field level. The European PROFIBUS standard EN50170 guarantees compatibility of all certified devices. 150 companies offer more than 800 products with PROFIBUS interfaces. Specification according to the standard EN50170: - FP0 DP slave unit or remote I/O unit - FP-Sigma DP slave units (FNS*) - FP2/FP2SH DP slave unit (FNS*) - FP-Sigma DP master unit - FP2/FP2SH DP master unit - PROFIBUS interfaces for VF-CE inverters and 8200 vector series inverters
*FNS = Flexible Netork Slave with exchangeable communication module, also for CANopen and DeviceNET.
|
 |
 |
|
Panasonic CANopen
|
Implies manufacturer-independent communication at field level. The CANopen standard guarantees compatibility of all certified devices. Specification according to the standard EN 50325-4: - FP2/FP2SH CANopen-Master - FP-Sigma CANopen-Master - FP-Sigma CANopen-Slave - FP2/FP2SH CANopen-Slave
|
 |
 |
|
Panasonic DeviceNet
|
Implies manufacturer-independent communication at field level. The DeviceNet standard guarantees compatibility of all certified devices. Specification according to the standard ODVA: - FP2/FP2SH DeviceNet-Master - FP-Sigma DeviceNet-Master - FP-Sigma DeviceNet-Slave - FP2/FP2SH DeviceNet-Slave
|
 |
 |
|
Panasonic Profinet IO
|
Implies manufacturer-independent real-time industrial ethernet communication. Two RJ45-port connectors with an integrated 2-port switch enable communication within any network topology (bus, ring, tree, star) reducing the need for expensive external switches. Specification according to IEC 61158/IEC 61784-1. Panasonic Profinet IO Device Unit complies with Profinet IO conformance class B. - FP2/FP2SH Profinet IO-Device - FP-Sigma Profinet IO-Device
|
 |
 |
|
MEWNET-W
|
RS485-Two-Wire-Circuit Communication at process level between PLC systems using low-cost two-wire circuitry. Data exchange via RS485 interface (Token Bus). Transmission rate: 500KBd Max. number of stations: 32 Max. distance: 800m Max. distance between stations: 200m
|
 |
 |
|
MEWNET-P
|
Optical Fibres Absolutely interference-free network for communication at process level using optical fibre technology. Data exchange between PLC systems of network (Token Ring). Transmission rate: 375KBd Max. number of stations: 63 Max. distance: 10km Max. distance between stations: 800m
|
 |
 |
|
MB-LINK – Modbus
|
Standardised industrial network in accordance with the Modbus protocol. The individual communication participants can be networked to a master via MB-LINK either point to point or as multidrop configuration. Transmission rate: 0.3 bis 38.4KBd Max. number of stations: 247 Max. distance: 1,200m (multidrop), 15m (point to point) Max. distance between stations: (see maximum distance)
|
 |
 |
|
C-NET
|
Computer-Network LOW COST network in master / slave process for communication between computer and control systems. Transmission rate: 9.6/19.2KBd Max. number of stations: 32 Max. distance: 1.2km Max. distance between stations: 1.2km
|
 |
 |
|
MEWNET-TR
|
The sensor/actuator bus MEWNET-TR provides low-cost transmission of digital I/O information at sensor / actuator and field level between a master connection assembly and decentralised terminals (slaves). Transmission rate: 500KBd, Max. number of stations: 32 Max. distance: 700m Max. distance between stations: 700m
|
 |
 |
|
TR-NET
|
The intelligent sensor / actuator bus terminals in the TR-NET from Panasonic make cost-intensive network masters superfluous in compact automation projects. Digital information from a sensor station is transmitted via two-wire circuitry directly to the associated station. Transmission rate: 500KBd, Max. number of stations: 32 Max. distance: 700m Max. distance between stations: 700m
|
 |
 |
|
MEWNET-F
|
Decentralised I/O Network for optimum-cost decentralisation. Minimum possible wiring outlay. Diagnosis, analysis and programming of master unit can be conveniently done ”in situ“. Transmission rate: 500KBd Max. number of stations: 32 Max. distance: 700m Max. distance between stations: 700m
|
 |
 |
|
S-LINK
|
The serial I/O bus for up to 128 components per port, uses two-wire signaling circuits and connects components in the multidrop system to reduce networking costs. Transmission rate: 28.5Kbit/s, Max. number I/Os: 128/ch. Max. distance: 200m (400m)
|
|