KW9M (standard type)
|
Bekijk informatie (PDF)
|
- Panel-mount type
- Input voltages that can be measured: up to 500V (L-L), 289V (L-N)
- Accuracy class according to
- EN62053-21 Class 1 (active power) - EN62053-23 Class 2 (reactive power)
- 4-line LCD display
- Up to 3 circuits can be measured (1P2L), (3P4L -> 1 circuit)
- Currents as low as 1mA can be measured
- Bidirectional energy measurement (energy produced and energy consumed)
- RS485 (Modbus RTU, MEWTOCOL protocol)
- USB port
- DC/AC power supply voltage
- Direct connection to 1A/5A current transformers (secondary side current)
- Display of electrical parameters:
- Currents - Voltages - Apparent power - Reactive power - Active power - Active energy - Reactive energy - Power factor - Sum of the 3 phases (e.g. current, energy, power)
|
 |
 |
 |
 |
 |
 |
|
KW2G
|
Bekijk informatie (PDF)
|
- DIN-rail mounting
- Measure energy produced and consumed
- Integrated RS485 interface (Modbus RTU/MEWTOCOL)
- USB port for easy PC connection
- Simultaneous measurement of power and pulse input
- Easy expansion
- Main unit can display measured values for both itself and expansion units
- Display of electrical parameters:
- Instantaneous power - Energy consumption - Current - Voltage - Power factor - Frequency, etc. - Conversion CO2 value
- Up to 8 circuits (1-phase, 3-wire and 3-phase 3-wire systems)
(16 circuits for 1-phase, 2-wire systems)
|
 |
 |
 |
 |
 |
 |
|
KW1M
|
Bekijk informatie (PDF)
|
- Screw and DIN-rail installation possible
- Integrated RS485 interface (Modbus RTU/MEWTOCOL)
- Automatic logging of measurement data at numerous selectable intervals (can be saved on SD card)
- Diverse alarm functions, e.g. when current consumption levels are exceeded
- Calendar function
- Suited for measuring 3-phase currents of up to 400V AC
- Monitors and displays the most important electrical parameters:
- Instantaneous power
- Energy consumption
- Current
- Voltage
- Power factor
- Frequency, etc.
- Display of calculated CO2 use
- Integrated pulse counter and hour meter
- Pulse output
- Free software that allows you to display the most important measurement values
|
 |
 |
 |
 |
 |
 |
|
KW8M
|
Bekijk informatie (PDF)
|
- High voltage input type for direct measurement of 400V loads
- Three-phase, four-wire system compatibility
- Data log function (AKW8111H)
- Direct input for secondary side of 1A/5A CT (AKW8115). Dedicated CTs are no longer required.
- Integrated counter & hour meter function
- Up to 99 Eco-POWER METERs can be connected to one master PLC
- Network compatibility
- Modbus - RS485 - MEWTOCOL (Panasonic proprietary network protocol)
|
 |
 |
 |
 |
 |
 |
|
KW7M
|
Bekijk informatie (PDF)
|
- DIN type, 22.5mm
- Easy mounting
- Control energy consumption, current, voltage
- Supports 400V AC power measurement
- Multiple inputs
- RS485
- Modbus / MEWTOCOL protocol
|
 |
 |
 |
 |
 |
 |
|
KW4M
|
Bekijk informatie (PDF)
|
- Supports 400V AC power measurement
- Control energy consumption (current, voltage)
- Built-in hour meter & counter function
- Up to 99 Eco-POWER METERs can be connected to one master PLC
- Supports 4 types of compact CTs
- Network compatibility
-Modbus (RTU) -RS485
- Pulse output
|
 |
 |
 |
 |
 |
 |
|
KE2S / KC2S
|
Bekijk informatie (PDF)
|
- Ideal for maintaining your facilities and machinery
- Built-in battery allows the units to be installed anywhere
- Compact size saves space. (DIN size: 24 x 48)
- Easy to install even in cramped spaces
- Numbers on the LCD screen are 8.7mm tall
- Easy to read
|
 |
 |
 |


|
|
|