| Size in mm (LxWxH) | 53,3x33x14,5 | 53,3x33x16,5 | 53,3x25x16,5 | 53,3x25x16,5 | 40/50x13x24 | 31/39x28,6x14,5 | |||||||||
| Features |
|
|
|
|
|
|
|||||||||
| Switching current | Max: 8A Min: 10mA |
Max: 8A Min: 10mA |
Max: 8A Min: 10mA |
Max: 8A Min: 10mA |
Max: 6A Min: 1mA |
Max.: 6A Min.: 1mA |
|||||||||
| Max. switching voltage | 500V DC 500V AC |
400V DC 400V AC |
400V DC 400V AC |
400V DC 400V AC |
30V DC 250V AC |
30V DC 250V AC |
|||||||||
| Contact arrangement | 4a2b | 4a4b | 2a2b | 3a1b | 2a2b, 3a1b, 4a2b, 5a1b, 3a3b | 2a2b, 3a1b, 4a2b, 5a1b | |||||||||
| Breakdown voltage between open contacts | 2500Vrms (Test voltage) |
2500Vrms (Test voltage) |
2500Vrms (Test voltage) |
2500Vrms (Test voltage) |
1500Vrms | 1500Vrms | |||||||||
| Breakdown voltage between contact sets | 4000Vrms (Test voltage) |
2500Vrms (Test voltage) |
2500Vrms (Test voltage) |
2500Vrms (Test voltage) |
2500Vrms/4000Vrms | 2500Vrms, 4000Vrms | |||||||||
| Breakdown voltage contacts to coil | 5000Vrms (Test voltage) |
2500Vrms (Test voltage) |
2500Vrms (Test voltage) |
2500Vrms (Test voltage) |
4000Vrms | 4000Vrms | |||||||||
| Surge withstand voltage | - | - | - | - | - | - | |||||||||
| Coil voltage | (DC) 5, 9, 12, 16, 18, 21, 24, 36, 48, 60V | (DC) 5, 9, 12, 18, 21, 24, 36, 48, 60V | (DC) 5, 9, 12, 18, 21, 24, 36, 48, 60V | (DC) 5, 9, 12, 18, 21, 24, 36, 48, 60V | (DC) 12, 16, 18, 21, 24, 48V | (DC) 5, 12, 18, | |||||||||
| Coil power | 390mW (5 to 24V) 420mW (36 to 60V) |
500mW | 500mW | 500mW | 360mW (4 poles) 500mW (6 poles) |
670mW | |||||||||
| Mounting method | PCB | PCB | PCB | PCB | PCB | PCB | |||||||||